• spe_5

    Finish

    Smooth / Glossy
  • spe_5

    Specific gravity

    1.43 ± 0.02
  • spe_5

    Mixed Solids (% by volume)

    45 ± 2%
  • spe_5

    Mixing Ratio

    3:1 (Component A: Component B vol/vol)
  • spe_5

    Colour

    Any colour as per Ritver shade card.
  • Description
  • USE
  • SURFACE PREPARATION
  • APPLICATION METHODS
  • TYPICAL PAINT SYSTEM
  • STORAGE AND SHELF LIFE
  • SAFETY PRECAUTION

Ritver Epoxy Topcoat HB is a High build top coat based on a selected epoxy resin and forms a two component product with a suitable catalyst. By virtue of the epoxy resin it has excellent resistance to mild acids, bases and other chemicals. It has outstanding mechanical properties combined with good flow and i s ve ry easy to apply. Can be an ideal top coat where normal alkyd based topcoat systems cannot be recommended. This product is two pack reactive performance coatings for specific end use such as floors under subcategory 10 of DM. VOC value for this product is less than 500g/l as per DM specs.

Substrates: Masonry, Concrete & Steel structures, pipes with suitable primers.
Area of Use: Interior steel structures.

A good surface preparation and following the method statement / recommended system procedure of Ritver is an ideal recommendation for the application of Ritver Epoxy Topcoat HB.

For Metals:
In case of mild conditions of application, remove the previous coat with a mechanical tool, wire mesh, or a mild sweep blast is to be done.In case of detailed Surface preparation is warranted, remove all wax, oil and grease should be removed by solvent cleaning in accordance with the guidelines given by SSPC-SP1. Where necessary remove weld spatter and round off all rough weld seams and sharp edges to a smooth surface. Ideally abrasive blast clean to a minimum standard of Sa 2½ Swedish Standard SIS 05 59 00 or ISO 8501-1:1988. Any surface defects revealed by blast cleaning should be ground, filled or treated in a suitable manner. After blasting, remove dust from the surface. The surface to be coated must be clean and dry with Ritver Epoxy Primer followed by Ritver Epoxy Topcoat HB.

For Aluminum: Degrease and abrade with Ritver Epoxy Thinner and wet-or-dry paper. Apply Ritver Etch Primer. Immediately follow with Ritver Epoxy Topcoat HB.

For Concrete: Ensure that the surface is sound. Remove laitance by thorough wire brushing, acid etching or sweep blasting. Blowholes and other defects should be filled with suitable filler. Ritver Epoxy Topcoat HB may be applied with an Ritver Epoxy Primer.

Exclusions for successful application include perpetually wet surfaces and also large cavities on metal and concrete surfaces.

Adequate ventilation is an ideal situation as it helps in drying and the good application itself. Avoid high humid conditions i.e., >95% when condensation is likely to interfere and also when the surface temperature is at least 3°C above dew point.

Mix Part A and B in the recommended ratio thoroughly until uniform taking care that no excess air bubbles are formed.

To be done by Airless spray 2000-2300 psi. Nozzle size: 0.015-0.018 inches or conventional spray at 50 – 60 psi. It can even be done with a roller. The product can be rolled or It is generally recommended to give a mist coat followed by a full coat.

A normal brush or a roller may be used for difficult shapes or touchup; however, additional coats may be required to achieve the recommended film thickness. The method of application is recommended for stripe coating welds, edges, rivets etc.

One can add Ritver Epoxy thinner to make a convenient dilution but care should be taken that good build up is made by subsequent coats too resulting in good deposition. Caution: Over diluting would result in a sag and run downs.

Ritver Epoxy Topcoat HB Ritver Epoxy Pigmented Primer 1 coat
Ritver Epoxy Topcoat HB 2 coats
Recommended system to be applied as per
surface preparation
*Or as per Ritver technical advice.
Ritver Acrylic 2K Topcoat 2 coats

Under dry and cool condition, storage stability can be sound up to 18 months in original sealed containers. In no way should the component A & component B be mixed and kept.

HANDLING
Disposal: As per the guidance and legislations of the local Authority e.g., by controlled landfill. In case of doubt, consult local authority. Do not empty into drains, sewers or other water courses.
Flash Point: 27°C and contains organic solvent.

Avoid contact with the skin and eyes. Wear suitable protective clothing such as overalls, goggles, dust mask and gloves. Use a barrier cream. Other industrial practices are applicable. Ensure that there is adequate ventilation in the area where the product is being applied. Do not breathe vapor or spray.
MSDS is available on request for the safe handling of this product.

FIRST AID
Eyes: In the event of accidental splashes, flush eyes with warm water immediately and obtain medical advice.
Skin: Wash skin thoroughly with soap and water or approved industrial cleaner. DO NOT USE solvent or thinners.
Inhalation: Remove to fresh air, loosen collar and keep patient rested.
Ingestion: In case of accidental ingestion DO NOT INDUCE VOMITING. Obtain immediate medical attention.